When one Chinese company says its brain-signal decoder is 90% accurate and another says 85%, there has been no common way to compare the two. “Different companies have used different datasets and metrics, so a 90 percent accuracy rate and an 85 percent accuracy rate could not really be compared,” Sun Cong, vice president of Wuhan Yiruide Group, told the Global Times on 25 November. “Hospitals and regulators had no way to judge which figure was more credible.”
That day in Wuhan, China’s Ministry of Industry and Information Technology (MIIT) launched the working groups that will write its brain-computer interface industry standards, and the organisers released a report on how decoding algorithms should be tested.
What was set up
The working groups belong to MIIT’s Brain-Computer Interface Standardisation Technical Committee, known as MIIT/TC4. Their launch was announced at the opening of a two-day “Standards Week” on 25 and 26 November, held jointly with the brain-computer interface subcommittee of China’s national information technology standards committee. Close to 160 experts and industry representatives attended.
There are eight groups: overall, hardware, software, data, product systems, applications, safety governance and the medical sector. Together they cover the field from research to use, and their member organisations include universities, research institutes, companies and hospitals.
- The overall group drafts standards on common technical principles, typical technical approaches and general testing and evaluation, and coordinates the other groups.
- The hardware group drafts standards for neural signal acquisition and for the interfaces that output preprocessed signals.
- The applications group covers industrial, consumer, transport and education settings, with standards for releasing application scenarios, deploying them and testing how products fit them.
The organisers included the China Electronics Standardization Institute (CESI), Huazhong University of Science and Technology’s brain-computer interface research institute, a Hubei provincial brain-computer interface innovation centre based at Tongji Hospital, and the Wuhan Optics Valley International BCI Innovation Centre. Over the two days the group leaders met, and each group discussed the standards approved for drafting in 2026. Tongji Hospital, Union Hospital, Huazhong University of Science and Technology and Wuhan University are among the Wuhan institutions taking part in drafting standards, said Tang Zhouping, Tongji Hospital’s party secretary.
MIIT set up TC4 in an announcement dated 4 June 2025, with 52 members and CESI as its secretariat, to draft and revise industry standards on brain-computer interface fundamentals, input and output interfaces, data, industry applications, and ethics and safety. In a plan dated 28 October and published on 3 November, MIIT approved nine new brain-computer interface industry standards under TC4, each due within 12 months. They cover product grading and classification, risk management capability, interface usability, fatigue monitoring systems, wireless communication for implanted devices, data management, algorithm and model management, sports training systems and attention monitoring systems.
A common test for decoders
The report released at the opening, the Research Report on Brain-Computer Interface Decoding Algorithm Evaluation (2026 edition), sets out a standard process for preparing test data, testing an algorithm, calculating its performance and analysing the results. It was validated in a case study on motor imagery tasks, in which a person imagines a movement.
“It is like giving decoding algorithms a unified ruler,” Sun said. He added that the framework could serve as a basis for procurement, regulatory review and reimbursement decisions, helping better products stand out and curbing exaggerated performance claims.
What China already has
TC4 writes industry standards. China’s first foundational national standards for the field, GB/T 47023-2026 on reference architecture and GB/T 47127-2026 on multimodal data formats, took effect on 1 August, and a third, on visual evoked potential data, followed on 1 October. All three are recommended national standards. Medical devices have their own track: the National Medical Products Administration (NMPA) has issued a medical-device standard on EEG datasets used by AI algorithms in brain-computer interface devices, which takes effect on 1 September 2027.
In August MIIT published a draft national guide to brain-computer interface industry standards, in seven parts running from foundations and hardware to applications and safety governance. It targets at least 40 standards drafted or revised by 2028, at least 10 international standards led or joined by China by 2028, and at least 80 standards in total by 2030.
Internationally, ISO and IEC published a reference architecture for brain-computer interfaces in September. China’s market regulator says a Chinese expert led the project, which came from ISO/IEC JTC 1/SC 43, the brain-computer interface subcommittee whose secretariat is held by China’s national standards body.
Signal: Why it matters
Standards decide what counts as evidence. A shared method for testing decoders could give Chinese hospitals, regulators and payers a common basis for comparing products; Sun’s own list of its uses runs from procurement to reimbursement. With an applications group covering industrial, consumer, transport and education uses alongside a medical-sector group, the committee’s work reaches markets beyond the hospital.
Companies are among the groups’ member organisations, which gives them a hand in drafting the standards their products will be measured against. Neuracle’s Shanghai medical device unit and the neurostimulator maker SceneRay are listed among the drafters of five of the nine approved standards, alongside CESI, Zhejiang University, Tianjin University and Tongji Hospital. CESI, which runs TC4’s secretariat, also supplies the chair of the international subcommittee: as of late 2025, SC 43’s chair was Yu Yuntao of CESI.
Where this sits on the four-jurisdiction posture map
Brain-Computer Interfaces, The Takeoff Era (Spring 2026), a Dargentic Intelligence report, classified four global regulatory postures on brain-computer interfaces: Rights-First (Chile), Horizontal Regulator (the EU, through the AI Act and GDPR), State-Patchwork (the US) and Industrial Builder (China and South Korea).
Industrial Builder (China). A ministry committee with a state institute as secretariat drafts standards in working groups that include companies whose products the standards will cover, under draft numeric targets, while China holds the secretariat of the international subcommittee.
Horizontal Regulator (European Union). In November 2025 DKE, Germany’s electrotechnical standards commission, proposed a European committee on brain-computer interfaces under CEN and CENELEC, Europe’s standards bodies, to keep standards consistent with EU law.
State-Patchwork (United States). US participation in JTC 1, including SC 43, runs through INCITS, which has a brain-computer interface committee. The FDA regulates medical brain-computer interfaces, implanted or not, as medical devices, while rules on neural data are being set state by state.
Not disclosed
Who leads each working group and how many members each has. The draft texts of the nine approved standards and when they will open for public comment. Who wrote the decoding evaluation report and whether it will be published in full. How the medical-sector group divides its work with the NMPA.
Forward Radar: What to watch
The first drafts of the nine approved standards, due within a year.
The final version of MIIT’s standards guide.
Whether the decoding evaluation method is used in NMPA reviews, hospital procurement or reimbursement decisions.
Sources
Translations from Chinese-language sources are Inside BCI’s.
Primary:
- MIIT: Announcement 2025 No. 11, establishing MIIT/TC4, 12 June 2025 (Chinese)
- MIIT General Office: Notice issuing the fifth batch of 2026 industry standard projects, 3 November 2026 (Chinese)
Coverage:
- China News Service: MIIT brain-computer interface standards committee working groups established, 25 November 2026 (Chinese)
- Global Times, Zhang Weilan: China sets up BCI standardization working group amid commercialization push, 25 November 2026
- Wuhan Science and Technology News via The Paper, Dai Yu: 2026 brain-computer interface Standards Week held in Optics Valley, 26 November 2026 (Chinese)
- Investor Network via Stockstar: MIIT approves nine brain-computer interface industry standards, 13 November 2026 (Chinese)
- Cooley: Your brain, their rules, the growing patchwork of neural data regulation, February 2026
Cross-reference to prior InsideBCI coverage:
- 16 August 2026: China’s first foundational BCI national standards took effect on 1 August 2026
- 27 August 2026: China puts brain-computer interfaces on the 15th Five-Year Plan ‘future industry’ list
- 17 September 2026: China issues a medical-device standard for AI processing of EEG data in brain-computer interfaces
- 23 October 2026: A Chinese expert led the new international blueprint for brain-computer interfaces
- 23 November 2026: Chinese state research institute counts 1,175 BCI companies worldwide